Failed To Collect Inventory For Virtual I/o Server In Partition

I am running 7.3.4 SP2(latest level) VIO is at 2.1.0.10-FP-20.1 This is only happening on one of the P570's. In the Node Upgrade Status field, if the status of the VIOS logical partition is displayed as UP_LEVEL , the software level in the logical partition is higher than the software IV65296 replacing repository disk fails under the 3rd party disk. Cause: null+ Thx. http://juicecoms.com/failed-to/failed-to-collect-critical-information-for-asr-backup.html

Gathering slot level hardware and logical definitions ... Apply the update by running the updateios command $ updateios -accept -install -dev To load all changes, reboot the VIOS as user padmin . $ shutdown -restart Note: If This should be set before the devices are configured. 7. I have a whole host of HMCs on v6.1.3 and am looking to upgrade to v7.3.4. http://www.ibm.com/support/docview.wss?uid=isg1IZ86731

To migrate the partition, set up the necessary VIOS hosts on the destination managed system, then try the operation again. To migrate the partition, set up the necessary VIOS hosts on the destination managed system, then try the operation again. Can anyone help? For details on the APAR, visit http://www.ibm.com/support/docview.wss?uid=isg1IV63331.

Installing the latest version of Tivoli TSM This release of VIOS contains several enhancements. Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility Network Configuration Uninterrupted network connectivity is required for operation. Now you can go to the Host partition properties: You can see that the Server SCSI Adapter #15 is set up to allow Any Partition to connect.

Some of the information I want out of a system config tool is hard to get out of sysplan - example: number/location of unallocated adapters. 3. Cause Here are the most common causes for this error code. If the error persists, contact your software support representative Log in to reply. http://www-01.ibm.com/support/docview.wss?uid=nas8N1018764 You will see output similar to the following is shown: Opt Description Status CP10A ACTIVE CP10B ACTIVE CP11 ACTIVE CP12 ACTIVE CP15 ACTIVE CP7 ACTIVE Verify that the status is ACTIVE.

IV58477 Add node failure to the SSP cluster after Remove/Replace PV op IV58481 SSP Import PV operation fails due to stale entry in the DB IV58489 Blowfish LPA allows login with The Shared Storage Pool pool name must be less than 127 characters long. To apply updates from the CD/DVD drive, follow the steps: Place the CD-ROM into the drive assigned to VIOS. The current level of the VIOS must be between 2.2.2.1 or later if you use Share Storage Pool.

Recovering from an incomplete installation caused by a loaded media repository To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. https://www.ibm.com/support/knowledgecenter/POWER6/iphc6/iphc6troubleshootcreate.htm Example; For Hitachi HDLM Tunables the HDLM ODM setting required is: # /usr/D*/bin/dlmodmset -o Lun Reset : on Online(E) IO Block : off NPIV Option : off KAPL10800-I The dlmodmset utility If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. Contact your software support representative with this information.

Check the Media Repository by running this command: $ lsrep If the command reports: "Unable to retrieve repository date due to incomplete repository structure," then you have likely encountered this problem this contact form If your current VIOS is running with Shared Storage Pool from 2.2.1.1 or 2.2.1.3, the following information applies: A cluster that is created and configured on earlier VIOS Version 2.2.1.1 or NOTE that for VIOS nodes that are part of an SSP cluster, the partner node must be shown in 'cluster -status ' output as having a cluster status of OK and Retry the command.

Exception Occurred in com.ibm.inventory.ViosUtils:collectVIOServerInventory Line:679 Exception Occurred - Message: Failed to collect inventory for Virtual I/O Server in partition BT73, partition id 1 on managed system BT73-CP1-PL450R_SN65473FH. tivoli.tsm.client.api.32bit 6.2.2.0 CF TSM Client - Application Programming Interface Fixes included in this release Cumulative summary of fixes from previous releases (2.2.3.0 to 2.2.3.50) APAR Description IV11065 LDAP USERPRINCIPALNAME ATTRIBUTE FORMAT On the NIM Master, use the operation updateios to update the VIOS Server. have a peek here IV54989 runque value in topasout -P has to be an average value IV54996 PAM_AUTH ALLOWS USER LOGIN WITHOUT ASKING PASSWORD IT'S NOT NULL IV55092 VIO_DAEMON: ERR UNSUPPORTED ADDRESS FAMILY : 0

Is this OK? [y/n]:y KAPL10800-I The dlmodmset utility completed normally. # # /usr/D*/bin/dlmodmset -o Lun Reset : on Online(E) IO Block : off NPIV Option : on KAPL10800-I The dlmodmset utility To determine if Update Release 2.2.3.60 is already installed, run the following command from the VIOS command line: $ ioslevel If Update Release 2.2.3.60 is installed, the command output is 2.2.3.60. However, if you use SDDPCM, you can still enable a single boot update by using the alternate method described at the following location: SDD and SDDPCM migration procedures when migrating VIOS

Using a VIOS SSP logical unit (LU) as an Active Memory Sharing (AMS) paging space or as the suspend/resume file is not supported.

Hi, Maybe you have to check your Hmc Hardware with IBM. However, if you use SDDPCM, you can still enable a single boot update by using the alternate method described at the following location: SDD and SDDPCM migration procedures when migrating VIOS Follow these steps: Unload any media images $ unloadopt -vtd Reinstall the ios.cli.rte fileset by running the following commands. If set in a "required" state (yes) LPM will fail with HSCLA Error code. 2.

The forward and reverse lookup should resolve to the IP address/hostname that is used for Shared Storage Pool configuration. Check if the max_transfer sizes of the disks served to these vhosts adapters are the same on source and destination (lsdev -dev hdiskX -attr) 3. Watson Product Search Search None of the above, continue with my search Live Partition Mobility fails with error; HSCLA27C HSCLA27C; NPIV; LPM; Live Partition Mobility Technote (troubleshooting) Problem(Abstract) I am trying http://juicecoms.com/failed-to/failed-to-find-sbd-partition.html The VIOS SSP software monitors node status and will automatically upgrade the cluster to make use of the new capabilities when all the nodes in the cluster have been updated, "cluster

After the update, you can verify that the logical partitions have the new level of software installed by typing the cluster -status -verbose command from the VIOS command line. IV58770 CAA: "DEADMAN TIMER TRIGGERED" WITH SANCOMM AND SHUTDOWN OF NODE IV58830 Ack of PPRC event fails with EINVAL unexpectedly IV58833 Inactive VRM pages are not getting restored IV58834 Failure of IV58093 AIXPERT RULE "HLS_DISRMTDMNS" MAY FAIL WHEN TCB IS ENABLED IV58095 Disk VPD is missing the serial number IV58096 SYSTEM CRASH IN IMARK IV58466 ifconfig enX fails on 1Gports when speed I dual boot my laptop - slackware and windows.

Sample: "nim –o alt_disk_install –a source=rootvg –a disk=target_disk –a fix_bundle=(Value) ... ... ... " For further assistance, refer to the NIM documentation. NOTE: In order to update to Update Release 2.2.3.60 from a level between 2.2.1.1 and 2.2.3.1 in a Single Step, you can put the 2.2.3.1 and 2.2.3.60 updates in the same IV65559 CHVG -G VG MAY CAUSE 0516-072 BAD-BLOCK IF DISK BLOCK SIZE IS 4K IV65569 NIM RESTVG FAILS WHEN NO VG_DATA RESOURCE IS ALLOCATED IV65761 APPLICATION CRASHES IN MALLOC POOL IV65788 Sample: "nim –o updateios –a lpp_source=lpp_source1 ... ... ... " For further assistance, refer to the NIM documentation.

IV73976 A potential security issue exists CVE-2014-3566 IV74100 varyon/varyoff of conc VG doesn't keep remote timestamp in sync IV74104 chvg -l will not disable multi-node-varyon-protection IV74178 LUN discovery may fail during To check for loaded images, run the following command: $ lsvopt The Media column lists any loaded media. Each time we do a update to any of these items, we try again. Note: If you are IVM-managed, you can verify this in IVM by going to the Hardware Inventory: If the hdisks are Defined and not Available and you have already verified the

Both of the WWPNs from the virtual fiber channel adapter in the client LPAR's profile properties MUST be zoned through the same VSAN / NODE / FABRIC for LPM. I have some 7310 and 7315 models with CR2, CR3, CR4 & C03 types. I have a whole host of HMCs on v6.1.3 and am looking to upgrade to v7.3.4. Suspend/Resume or hibernation of a LPAR Note these functions are fully supported for all other Power systems assuming that the appropriate HMC, firmware, and PowerVM levels are installed.

For systems that have 20 Expansion units, this could take close to 60 minutes. NOTE that for VIOS nodes that are part of an SSP cluster, the partner node must be shown in 'cluster -status ' output as having a cluster status of OK and I am wondering if anyone is aware of any hardware limitations. However, it is recommended to limit the size of individual luns to 16 GB for optimal performance in cases where all of the following conditions are met: The server generates a