Click Start > Run.  Type cmd and click OK to open a command prompt. Updated on 2012-08-08T08:25:28Z at 2012-08-08T08:25:28Z by Sup3rior friesland 110000RJ4N 64 Posts Re: Windows 2008 Event ID 129 ql2300 error while connecting to SAN storage 4700 ‏2012-01-07T17:06:05Z This is the accepted You can simply use autogenerated SymbolicLink \Device\HardDiskX\Partition0 for RAW volume, and \Device\HardDiskX\Partition(1,2,3...) for logical partitions if you are writing your own device drivers.if you need still more indepth detailIOCTL_VOLUME_GET_VOLUME_DISK_EXTENTS can determine The standard microsoft support response of "Check with your storage vendor" is misleading to those who actually need a fix. [In the example of a VM environment, the virtualization software is have a peek here

Select appropriate option to save the settings and return to the Fast!UTIL Options menu. More... Only remove them from VMWare or Physical targets.  Solution To resolve this issue, complete the following steps on the Image that is hosted on the VMWare Hypervisor: Uninstall the Provisioning Services This caused a high latency period in access to LUNs, and thus, caused delays in I/O to the point where Exchange could fail. http://www.eventid.net/display-eventid-129-source-elxstor-eventno-8622-phase-1.htm

Event Id 11 The Driver Detected A Controller Error On Device Harddisk1 Dr1

stornieren Citrix技术支持 自动翻译 本文是通过自动翻译系统翻译的,未经人工审查。Citrix 提供自动翻译以提高对支持内容的访问,但自动翻译的文章可能包含错误。对于因使用自动翻译的文章导致出现的不一致、错误或损害,Citrix 不承担任何责任。 取消 Citrix技術支持 自動翻譯 這篇文章被翻譯由一個自動翻譯系統,並沒有受到人們的審查。 Citrix提供自動翻譯,增加獲得支持的內容;但是,自動翻譯的文章可能可以包含錯誤。思傑不負責不一致,錯誤或損壞因使用自動翻譯的文章的結果。 取消 Citrixのサポート 機械翻訳 この技術情報資料は、機械翻訳システムによって翻訳されたもので翻訳者によるレビューは受けていません。Citrixでは、サポートコンテンツへアクセスする機会を増やすため、機械翻訳を提供しています。しかしながら、機械翻訳の品質は翻訳者による翻訳ほど十分ではありません。誤訳や、文法、言葉使い、その他、たとえば日本語を母国語としない方が日本語を話すときに間違えるようなミスを含んでいる可能性があります。機械翻訳の品質、および技術情報資料の内容の誤訳やお客様が技術情報資料を利用されたことによって生じた直接または間接的な問題や損害については、いかなる責任も負わないものとします。 キャンセル Поддержка Citrix Traducao automática Эта статья была переведена автоматической системой перевода и не был рассмотрен The cluster node with a failed path to a DS4000 controller will issue a failover command of all logical drives that were mapped to the cluster group to the controller that Shifted the blade to a new chasis 3. Unanswered question This question has not been answered yet.

If ten years ago it was still common to see an entire company using just one server, these days that's no longer the case. Citrix recurre a la traducción automática para mejorar e incrementar el acceso a páginas de asistencia técnica. English: This information is only available to subscribers. Event Id 11 Disk The Driver Detected A Controller Error some of the conventions you would write is PhysicalDrive{x} -> QueryDosDevice -> Device\Harddisk{x}\DR{x}where DR[x] might represent the partition of a harddisk.

After a programmed interval, the nodes that did not have failed path will issue failback command for the logical drives because they can access the logical drives both controllers, resulting in Event Id 11 The Driver Detected A Controller Error On Device Raidport0 Even with 5 minutes per server (to check the logs and other parameters), it may take an hour to make sure that everything is ok and no "red lights" are blinking When a request completes, the timer is refreshed with the timeout value of the head request in the pending queue. go to this web-site The timer is decremented once per second.

The disk timeout value is a tunable parameter in the registry at: HKLM\System\CurrentControlSet\Services\Disk\TimeOutValue. Event Id 11 Windows 7 This SRB is sent to the port driver as part of the I/O request packet (IRP). Dropped requests can be caused by faulty routers or other hardware problems on the SAN. Press ESC twice to get to the "Save setting" menu.

Event Id 11 The Driver Detected A Controller Error On Device Raidport0

For Windows, change the DisableLunRebalance registry setting of the HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\rdacdisk\Parameters registry key from 0 to 3 in each cluster node. my response When the unit is reset, all outstanding requests are completed with an error and they are retried. Event Id 11 The Driver Detected A Controller Error On Device Harddisk1 Dr1 No obstante, la información publicada mediante traducción automática puede contener errores. Event Id 15 Disk Concepts to understand: What is a DLL?

Then, select the Configuration Settings menu option followed by Advanced Adapter Settings menu option to display the menu that the Port Down Retry Count parameter is displayed. navigate here x 4 Private comment: Subscribers only. This is the accepted answer. However, you must reboot the servers for the changes to become effective. Event Id 11 Disk Controller Error

Show: 10 25 50 100 items per page Previous Next Feed for this topic ⚑ Deus Ex Machina ➽ Eventlog Lookup DxM Home | Registry Deus Ex Machina » Eventlog » Thanks & Regards Sriram More... Next is the volume manager, followed by the disk driver. http://juicecoms.com/event-id/event-id-1058-on-domain-controller.html You can get a list of these using hbacmd listhbas.

Reboot the server +2. Event Id 11 Atapi Unfortunately we are not able to provide in depth 1:1 troubleshooting on this blog, I would encourage you to open a case with Microsoft Support to further investigate the problem you A utility, SMRegUpdate.reg, is provided in the SMUtil host software package to facilitate this registry change.

What is causing the “The description for Event ID ( … ) in Source ( …. ) cannot be found… “?

Next start-up 1st cluster node and the the 2nd cluster node. We have collected logs and have been working the hardware support angle for 2 days. You can view the ghost NICs in the Device Manager, as shown in the following screen shot: Additional Resources How to Troubleshoot a Target Device not Booting into a vDiskDeploying Event Id 15 Disk Vmware Was the information on this page helpful?

For example, ATAPORT.SYS is the port driver for ATA devices, and STORPORT.SYS is the port driver for SCSI devices. This is also the recommended method to change NVSRAM setting in Intel Itanium II 64bit (IA64) servers. I have never seen software cause an Event ID 129 error. this contact form did the critical updates for the blade as below HS22 UEFI 1.16 HS22 IMM 1.31 LSI SAS 1064E firmware 1.30.10.00 SAS drive firmware SC17 Qlogic FC card v9.1.9.25 Now the cluster

Select appropriate option to save the settings and return to the Fast!UTIL Options menu. The windows system log message shows the error msg as Event ID 129 with source as ql2300.Msg displays as below Reset to device, \Device\RaidPort1, was issued. So, as long as requests complete the timer will never go to zero. The disk resources are automatically getting failed over to the second node whenever there is high disk I/O utilization is occurring in first node.