Sorry, we couldn't post your feedback right now, please try again later. Type the following commands at a command prompt. Tags: vss| Posted underIT Administration| 3 Comments VSS Errors While Formatting Drive Mark Berry November 2, 2010 In Server 2008 R2, I started a full (not quick) format on an external I typed vssadmin list shadows at a command prompt and it showed that there is a shadow copy on some kind of virtual volume (\\?\Volume{2eb5f062-fd3d-11d8-8bb5-806d6172696f}\). have a peek at this web-site

Try one of these handy commands:  vssadmin list volumes or mountvol. Solution There is no specific resolution from Microsoft for this error. Add Cancel × Insert code Language Apache AppleScript Awk BASH Batchfile C C++ C# CSS ERB HTML Java JavaScript Lua ObjectiveC PHP Perl Text Powershell Python R Ruby Sass Scala SQL The Volume Shadow Copy service is not started.

Error Calling A Routine On The Shadow Copy Provider 12294

Solution A supported hotfix is available from Microsoft which can be downloaded from:http://support.microsoft.com/hotfix/KBHotfix.aspx?kbnum=932532&kbln=en-us For further assistance please refer Microsoft KBhttp://support.microsoft.com/kb/932532 Go to top 0x80042324: The remote is running a version of This issue occurs when the shadow copy was created from volumes that span multiple partitions. As soon as I did that, I was able to access anything related to VSS.

TECHNOLOGY IN THIS DISCUSSION Microsoft 504578 Followers Follow IIS Microsoft Windows Server Read these next... © Copyright 2006-2017 Spiceworks Inc. Recent Posts Set Up VLANs with Tomato and a Cisco Small Business Switch Read Registry from Restored Backup GoldMine Pending Tab Preview Won’t Stay Hidden Malwarebytes 3 Upgrade Starts Premium Trial Another revert cannot be initiated until the current revert completesDescriptionSolution0x8004230e: The given shadow copy provider does not support shadow copying of the specified volumeDescriptionSolution0x8004230d: The object already existsDescriptionSolution Disclaimer: The steps Event Id 12293 Vss Server 2012 Volume path: C:Volume name: \\?\Volume{69777be9-2531-11db-9fe3-806e6f6e6963}Volume path: E:Volume name: \\?\Volume{ecf4d8bf-64c9-11dd-8b32-001320b36978}Volume path: F:Volume name: \\?\Volume{4ddf10c5-58aa-11da-8302-001320b36978} In Scheduled tasks, delete the "ShadowVolumeCopy" commands that do not match the IDs listed in your results.

Anyway, the issue in my case was the hard drives were replaced in the raid array before I took over in IT.  The system was imaged first, then the drives were Event Id 12293 Kms When the storage limit is reached, older versions of the shadow copies will be deleted and cannot be restored. Multiple Backups Ensure that the backup is not running at the same time as another backup, as the custom provider may only allow one snap-shot at a time. check these guys out I got a message telling me it couldn’t display the shadow copy information, and a bunch of nasty messages in the Application event log with discouraging phrases like “catastrophic failure.” More...

Keep in touch with Experts ExchangeTech news and trends delivered to your inbox every month Membership How it Works Gigs Live Careers Plans and Pricing For Business Become an Expert Resource Failed To Retrieve Volumes That Are Eligible For Shadow Copies Note that the "sleep" mode I'm referring tois an internalfeature of the Seagate drive-it is not under the control of Windows Power Options in the Control Panel. Please see the system and application event logs for more information 0x80042306 The shadow copy provider had an error. Solution Check that the Event Service and VSS have been started and also check for errors associated with those services in the error log.

Event Id 12293 Kms

Check for associated errors in the event log Description The writer infrastructure is not operating properly. Then I deleted the obsolete task, which had the same volume ID as the event reported. Error Calling A Routine On The Shadow Copy Provider 12294 c. Event Id 12293 Vss Server 2008 After the reboot, the "vssadmin list shadows" command showed "No shadow copies present in the system," and DriveImage XML was able to create a new shadow copy and do the backup.

Log Name: Application Source: VSS Event ID: 12293 Level: Error Volume Shadow Copy Service error: Error calling a routine on a Shadow Copy Provider {b5946137-7b9f-4925-af80-51abd60b20d5}. Check This Out Scroll down and double click theMicrosoft Software Shadow Copy Provider. VSS believes the system is in setup process Check the status of the system by following these steps: a. When this limit is reached, the oldest shadow copy will be deleted and cannot be retrieved. Vss 12298

There is no other backup software installed.   There are three drive partitions: One for the operating system, one for data storage, and one as the Windows Server Backup location. if I right click on a drive letter and click the option "Configure shadow copies", I get a properties window with the C-drive, F-drive, and R-drive volumes listed and the ability A component with the same logical path and component name already exists. Source VSS issues when backing up System State and Shadow Copy Components Article:000085641 Publish: Article URL:http://www.veritas.com/docs/000085641 Support / Article Sign In Remember me Forgot Password? Don't have a Veritas Account? Create a

Go to top 0x80042314L: VSS encountered problems while sending events to writers Description The system was unable to hold I/O writes. B5946137-7b9f-4925-af80-51abd60b20d5 Take backup of the Key: HKLM\system\CurrentControlSet\Services\VSS\VssAccessControl. 2. A bad block error was also logged at exactly the same time.

Perform a backup operation to verify that the issue is resolved.

Continue reading Question has a verified solution. Microsoft Customer Support Microsoft Community Forums TechCenter   Sign in United States (English) Brasil (Português)Česká republika (Čeština)Deutschland (Deutsch)España (Español)France (Français)Indonesia (Bahasa)Italia (Italiano)România (Română)Türkiye (Türkçe)Россия (Русский)ישראל (עברית)المملكة العربية السعودية (العربية)ไทย (ไทย)대한민국 (한국어)中华人民共和国 (中文)台灣 If not, set it to Start. Vss Event Id 8193 c.Register the DLLs (click here).

Determine the current Volume IDs for VSS with the following command line a command shell: vssadmin list volumes The result will look like this: vssadmin 1.1 - Volume Shadow Copy Service Go to top 0x8004230d: The object already exists Description The object is a duplicate. Please see the system and application event logs for more information Description This error occurs when a VSS provider blocks the creation of the VSS snapshot. have a peek here Please retry later your snapshot creation." However to the best of my knowledge there are no other backups or other VSS-aware processes running.

Anyone got any ideas? Not Fixed Alas, when DriveImage XML completed and exited, I still had a volume shadow copy on the volume, and the next time I ran DriveImage XML, it gave me the However, if I right click on a drive letter and click the option "Configure shadow copies", I get a properties window with this error: Failed to retrieve volumes that are eligible In the event log, there were some new messages after running the suggested set of commands: Event ID: 8225 Level: Information The VSS service is shutting down due to shutdown event

Event ID: 8193 Level: Error Volume Shadow Copy Service error: Unexpected error calling routine IEventSystem::Store. When I tried to run the backup interactively, DriveImage XML told me that it "Could not initialize Windows Volume Shadow Copy Service (VSS)" and that the error code was 80042316. This is more common during periods of high disk activity or on disks that are heavily fragmented. Did you change the allowed space for shadow Copies?

and Event ID:7001 VssAdmin: Unable to create a shadow copy: Catastrophic failure Command-line: "C:\windows\system32\vssadmin.exe Create Shadow/ AutoRetry=5 /For=\\?\Volume{93776545-8c72-11dd-96c5-001279a52c15}\". Another revert cannot be initiated until the current revert completes. C:\> So it looks as the file system needs to be fixed. In this scenario, the VSS writer is not successful when it tries to create a snapshot and you receive the following error code: 0x80042301.

ClickClassicView in theTaskspane. Cause Volume shadow copy DLLs are corrupted. Cause This is due to a problem with the VSS when performing backups of any open files or files that are in use at the time of the backup. If the snapshots are not imported, the import operation fails.